- Add an 'Outport' block connect the voltage signal to it.
- Then, configure the "Data Import/Export" in the "Model Configuration Parameters" to save time and voltage in the base workspace by checking Time and Output checkbox, also change "Format" to "Array".
- In MATLAB convert the arrays into a table by:
How to save the graph obtained with Simulink's scope as numerical data
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I have plotted voltage and current using the scope. I want to save the waveforms as a table of time and voltage values with a sampling time of 0.001 seconds.
0 comentarios
Respuesta aceptada
Epsilon
el 25 de Sept. de 2024
Editada: Epsilon
el 25 de Sept. de 2024
To export the voltage and time, use the 'outport' block to save the data in the MATLAB base workspace and then convert them into a table.
waveformTable=table(tout,yout)
%tout and yout are the default variable names defined while configuring "Data Import/Export".
Note: Model needs to be pre-configured to have a sampling time of 0.001 seconds as the sampling time depends on the parameters passed in the block used.
Link to documentation on Outport: https://www.mathworks.com/help/simulink/slref/outport.html