I cannot flip manual switch while in monitor and tune
37 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Malek
el 8 de Oct. de 2024
Editada: Vorrapath Kokaew
el 29 de Oct. de 2024 a las 12:09
Hello,
When running a simulation on an Arduino Mega 2560 through monitor and tune, I cannot change the position of any manual switch in my block diagram. I am running the simulation on the board and the sim is running on external mode through XCP on Serial. Any help would be much appreciated.
2 comentarios
Abhinav Aravindan
el 8 de Oct. de 2024
Could you share the Simulink model file to understand the issue better?
Respuesta aceptada
Amal Raj
el 28 de Oct. de 2024 a las 10:08
Hi Malek, I think you are faced with a bug in 2024b.
The workaround would be to update Default Parameter Behavior parameter drop-down value to Tunable in the config set.
This will solve the issue you are facing. You can even try working with other versions of MATLAB, and you should be fine.
Regards,
Amal
1 comentario
Vorrapath Kokaew
el 29 de Oct. de 2024 a las 12:04
Editada: Vorrapath Kokaew
el 29 de Oct. de 2024 a las 12:09
So, do I. I use ESP32 with arduino package that message shown Cannot change the model '.......' while the simulation is running. Anyway, I already follow the Amal Raj suggestion that WORK!!!!
Thank a lot
Más respuestas (0)
Ver también
Categorías
Más información sobre Modeling en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!