I cannot flip manual switch while in monitor and tune
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Malek
el 8 de Oct. de 2024
Hello,
When running a simulation on an Arduino Mega 2560 through monitor and tune, I cannot change the position of any manual switch in my block diagram. I am running the simulation on the board and the sim is running on external mode through XCP on Serial. Any help would be much appreciated.

2 comentarios
Abhinav Aravindan
el 8 de Oct. de 2024
Could you share the Simulink model file to understand the issue better?
Respuesta aceptada
Amal Raj
el 28 de Oct. de 2024
Hi Malek, I think you are faced with a bug in 2024b.
The workaround would be to update Default Parameter Behavior parameter drop-down value to Tunable in the config set.

This will solve the issue you are facing. You can even try working with other versions of MATLAB, and you should be fine.
Regards,
Amal
1 comentario
Más respuestas (0)