FMU issue while setting parameter

17 visualizaciones (últimos 30 días)
Saurabh Dhakate
Saurabh Dhakate el 28 de Oct. de 2024 a las 16:06
Respondida: Gayatri el 28 de Oct. de 2024 a las 16:11
We have an FMU that imports successfully into Simulink. However, I'm struggling to set parameters from the workspace. I've tried using various Simulink callbacks but it doesn't seem to affect the FMU's parameters. I want to set parameters once at the start of the simulation.

Respuesta aceptada

Gayatri
Gayatri el 28 de Oct. de 2024 a las 16:11
Hi Saurabh,
You can modify the parameters using the following MATLAB commands:
blockPath = 'model_name/block_name';
blockHandle = getSimulinkBlockHandle(blockPath, true);
set_param(blockHandle, 'parameter_name', 'parameter_value');
Please refer the below documentations for 'set_param' and 'getSimulinkBlockHandle' functions:
I hope it helps!

Más respuestas (0)

Categorías

Más información sobre RF Blockset Models for Transceivers en Help Center y File Exchange.