"Modelling option" for RLC (Three-phase) non-existent
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Power systems simulations onramp 2.1, Blocks, Task 4 requires you to change the "Modelling option" of a RLC (Three-phase).
Given images in the onramp it seems that in the past the "Modelling option" used to exist but now it has been replaced with "Electrical connection" (as shown in picture below).
However dispite the option no longer existing, the onramp will not let you proceed unless you have changed the "Modelling option" which is not possible.
If anyone can be of any help please let me know.

1 comentario
Ammar
el 9 de Sept. de 2025
There is a bug in this task, I did the task as described but still the first task appears to be unsolved please matlab update the power systems simulation onramp course and remove this bug, the bug exists in three phase systems, three phase domain, 2/3 blocks, task 4 " Does the following block have the correct parameter settings?
RLC (Three-Phase):
ComponentPath: ee.passive.rlc_assemblies.rlc.Xabc "
the is in this check mark please solve it in the nearest time possible

Respuestas (2)
Vinay
el 30 de Oct. de 2024
The 3-phase RLC block offers two modeling options: 'composite three-phase' and 'expanded three-phase'. The 'composite three-phase' ports represent three individual electrical conserving ports with a single block port and 'Expanded three-phase ports' represent the individual phases of a three-phase system using three separate electrical conserving ports.
However, connecting 'RLC block' with expanded port to a voltage source modeled as a 'composite' system results in an error. The issue can be resolved by changing the modeling option of the RLC block to 'composite three-phase' in the electrical connection settings.
Kindly refer to the below documentation of “RLC three phase” for more details:
I hope this helps!
0 comentarios
Abinash U
el 5 de Nov. de 2024
Change the Modeling option of the RLC (Three-Phase) block to Expanded three-phase ports.
Connect the a, b, and c phases of the blocks Voltage Source (Three-Phase) and RLC (Three-Phase).
Add a Phase Splitter block and use it to connect the RLC (Three-Phase) block to the Grounded Neutral (Three-Phase) block.
When you Submit your model, you can see that the configuration does not affect simulation values.
0 comentarios