Why are the characteristic points of the PV curve in the PV Array block, particularly the open circuit voltage, shifted in the simulation?
35 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Israfil-Cihan
el 8 de Nov. de 2024 a las 11:15
Respondida: Vinay
el 18 de Nov. de 2024 a las 6:56
0 comentarios
Respuestas (1)
Vinay
el 18 de Nov. de 2024 a las 6:56
The PV array block displays the I-V and P-V characteristics for specified irradiances and fixed temperature. The module here uses irradiances values of [1000 500 100] and temperature of 25 deg.C.
The 'open circuit voltage(Voc)' is a function of temperature and varies as
where β is the Temperature coefficient of Voc (%/deg.C) with default value of -0.36099
The issue is occuring because the value of the β is different from the default value causing the deviation from the optimum value of open circuit voltage. The default value shows the desired behavious of the 'Voc' as speciifed in the module.
Kindly refer to the below documentation of “PV array” for more details: https://in.mathworks.com/help/releases/R2024a/sps/powersys/ref/pvarray.html?searchHighlight=pv%20array&s_tid=doc_srchtitle
0 comentarios
Ver también
Categorías
Más información sobre Circuits and Systems en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!