Cannot run Referenced model in accelerator mode
    19 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
    Jake Gareau
 el 19 de Nov. de 2024
  
    
    
    
    
    Respondida: Abhas
      
 el 3 de Dic. de 2024
            I am unable to run a referenced model in accelerator, I have no issue doing so when the model is opened as the top model but once it is included in another model and individually set to accelerator while the rest of the model is set to normal, then it doesnt work.
Invalid run-time parameter registration in S-function 'sfun_spssw_discc' in model 'MyModel'. An S-function can register run-time parameters only if the S-function is being inlined.  To be able to reference the model 'MyModel', the S-function 'sfun_spssw_discc' needs to set the option SS_OPTION_USE_TLC_WITH_ACCELERATOR and it needs to have a TLC file.
I am not intentionally using any S - functions so I am a little unsure what to do with this error message
2 comentarios
  Gayathri
 el 20 de Nov. de 2024
				@Jake Gareau, Can you provide the simulink models so that I can take a look to find the issue.
Respuesta aceptada
  Abhas
      
 el 3 de Dic. de 2024
        To address this issue, try using "powergui". Navigate to "preferences" and enable the option called "Use TLC file when in Accelerator Simulation Mode and for code generation".
You can refer the below MathWorks documentation links to have a better understanding:
- https://www.mathworks.com/help/sps/powersys/ref/powergui.html#mw_081370b9-45b5-4a1f-9710-94f3835bf2cc
- https://www.mathworks.com/help/simulink/sfg/ss_option_use_tlc_with_accelerator.html
I hope this helps!