- The block "Wye-Connected Load" is to be configured as a "series RL" load.
- But, by default, it also models stray capacitance. You can verify this by going to the "Parasitics" drop-down found in the "block parameters" of "Wye-Connected Load". You can see that "Parasitic Parallel Conductance" is set to its default value of 1e-6.
- Change the "Parasitic Parallel Conductance" to the value of "0" as shown below:
Simulink onramp 3.1 represent power systems components task 5 error
30 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Miguel Aybar
el 26 de Nov. de 2024
Comentada: Miguel Aybar
el 5 de Dic. de 2024
me esta dando este error la tarea, pero se ha hecho todo desde el inicio correctamente
Simulink onramp 3.1 represent power systems components task 5 error
0 comentarios
Respuesta aceptada
Shivam Gothi
el 2 de Dic. de 2024
As per my understanding, you have completed tasks 1-4 of Power Systems Simulation Onramp successfully, but not able to complete task-5, even after following all the instructions carefully.
I also encountered same issue, but resolved it in the following way:
After making the above change, submit the task-5 by clicking "submit" button. You will see that your test is now passed as shown below:
I hope you find this useful !!