"block choice " button doesn't seem on Simulink

6 visualizaciones (últimos 30 días)
Bunyamin
Bunyamin el 27 de En. de 2025
Comentada: Bunyamin el 1 de Feb. de 2025
ı m tryna prepare a battery simulation with simulink but when ı push right click on "battery-table based" , and then ı go simscape button, and ı just only see "log simulation data" . Have you any reccomend for this problem? It s probably an easy solution, but ı can't

Respuestas (1)

Vinay
Vinay el 30 de En. de 2025
The 'block choice' is disabled in the MATLAB R2023b for the 'Battery' block. The thermal port can be modeled by enabling the thermal port in the block parameters.
  1. Open the 'Battery' block parameters.
  2. In the 'Thermal' tab , change 'Thermal port' as 'Model'
  3. Model the 'Thermal mass' parameter for the block.
Also the modeling option can be configured by enabling the 'Fade characteristic' in the block parameter as shown below
Kindly refer to the below documentation of 'Battery' and Matlab answer for more details
I hope this helps!
  1 comentario
Bunyamin
Bunyamin el 1 de Feb. de 2025
As you said, it s done. I changed "thermal port and the others options(by the way there is too an option for the SOC port ) " Thanks for helping.