Regarding deconvoultion using a point-spread function

3 visualizaciones (últimos 30 días)
I am deconvoluting an image with a simulated point-spread function (PSF), and the top pixels of my image obviously have their intensity decreased. The intensity of the top pixels should, in theory, be the highest. How do I adress this in a reasonable way?
load('data');
image2=deconvwnr(image1,PSF,0.5);
figure(), hold on
subplot(2,1,1), imagesc(image1), axis off, title('Original Image')
subplot(2,1,2), imagesc(image2), axis off, title('Deconvoluted Image')
  2 comentarios
Walter Roberson
Walter Roberson el 17 de Feb. de 2025
I notice the line in the documentation,
  • The output image J could exhibit ringing introduced by the discrete Fourier transform used in the algorithm. To reduce the ringing, use I = edgetaper(I,psf) before calling deconvwnr.
Perhaps you could try that?
Sebastian Daneli
Sebastian Daneli el 17 de Feb. de 2025
Editada: Sebastian Daneli el 17 de Feb. de 2025
@Walter Roberson, I'll try it.

Iniciar sesión para comentar.

Respuesta aceptada

Catalytic
Catalytic el 18 de Feb. de 2025
load('data');
tmp=[flipud(image1);image1];
tmp=deconvwnr(tmp,PSF,0.5);
image2=tmp(end/2+1:end,:);
figure(), hold on
subplot(2,1,1), imagesc(image1), axis off, title('Original Image')
subplot(2,1,2), imagesc(image2), axis off, title('Deconvoluted Image')

Más respuestas (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by