I added a constant heat flow source to the pipe but I couldn't see any temperature increase to the fluid which flows

4 visualizaciones (últimos 30 días)
I have added the necessary inputs that I have given to each block in the image attached. Basically, I need to model the heat transfer from the motor to the heat exchanger which i just replaced to a pipe with a constant heat flow source (which will represent the cooling power needed) . For the above mentioned objecvtive, suggest me if you have better solutions and ideas and also if you could help me understand why this solution doesn't work and how to fix it that would be great.
  1 comentario
Ashwin
Ashwin el 18 de Mzo. de 2025
@Yifeng Tang : Hi Tang, thought you could help me fix this issue.. if you could direct me to the right path that would be appreciated. Looking forward to hear from you!

Iniciar sesión para comentar.

Respuestas (1)

Yifeng Tang
Yifeng Tang el 18 de Mzo. de 2025
This should work fine. This is how heat is added to the coolant in some examples in the Documentation as well, like Electric Vehicle Thermal Management. Snapshot below:

Categorías

Más información sobre Thermal Liquid Library en Help Center y File Exchange.

Productos


Versión

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by