RC circuit Simulation results do not match look up table
7 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hello,
I am using this RC circuit simulation with my lab data. I have a 2.35Ah capacity battery, with a discharge pulse of 2.35A (1C). I put my HPPC test in RC circuit as in the picture of LUT code (first column)
In order to match the default RC circuit with my case, I remove all step blocks my setting them 0. Pulse generator is set with Ampitude = -2.35, Period= 3600s, Pulse width 10%, which mean I have 10 pulses, each pulse pull 10% of capacity.
The thing is the paramters that I put in the LUT is different from the data simulated. I put in R0=0.0607 Ohm. After I have the simulation, when get the ohmic voltage drop (the second when pulse start) / 2.35A. I got 0.0640 Ohm. It is close but not exactly. I don't know if I did something wrong or it is how simulation works or we have to do the exact procedure as in default simulation of matlab.
This is the default model: https://www.mathworks.com/help/simscape/ug/lithium-battery-cell-one-rc-branch-equivalent-circuit.html#d126e36758
Please help! Thank you so much in advance



1 comentario
Yifeng Tang
el 2 de Abr. de 2025
You may want to include the model files and scripts so the community can better help identify the issues.
Respuestas (0)
Ver también
Categorías
Más información sobre Electrical Systems en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!