How to get unity power factor in three phase rectifier by hysteresis current controller
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
attain unity power factor in input side by hysteresis current controller
0 comentarios
Respuestas (5)
Purushottama Rao
el 20 de Jun. de 2015
Steps: 1) Sample the input line voltage signal. Use a PLL for syncronization, the output of which is a unit mag sinusoidal signal inphase with the line voltage. 2) Prepare the ref current. This can be obtained by multiplying the required curret rms value with the PLL output. 3) Measure the input current 4) Calculate the error between the above two currents 5) Define a hystresis controller with the defined hystersis level. Relay block in simulink does this for you. Hystersis limits defines the switching frequency and THD. 6) Pass the output from hystersis to the switches directly.
It should give you the required output. ALL THE VERY BEST