problem while tuning PID controller
Mostrar comentarios más antiguos
I try to tune a PID-Controller in Matlab2010b if i use a discrete one i get the error Message "The second input argument of the "d2d" command must be a positive scalar." if i use a continuous one i get "Input to SVD must not contain NaN or Inf." what i have to pay attention that this block works fine? My system can became NaN due to a Sqrt-expression....
Respuesta aceptada
Más respuestas (4)
Arkadiy Turevskiy
el 12 de Dic. de 2011
0 votos
Can you provide the plant model?
Martin1986
el 13 de Dic. de 2011
0 votos
Yoni
el 19 de En. de 2012
0 votos
Hi Martin,
I've had the same problem.
It seems the discrete PID option does not handle a sampling time of "-1" (should have inherited the sampling time it that case)
So the workaround for your problem is to enter your own explicit expression for the sampling time. do not leave it on "-1".
This should eliminate the "The second input argument of the "d2d" command must be a positive scalar."
Cheers, Yoni
1 comentario
Nail
el 14 de Mayo de 2018
Also, simulation time must not be set to "inf".
Martin1986
el 8 de Feb. de 2012
0 votos
Categorías
Más información sobre PID Controller Tuning en Centro de ayuda y File Exchange.
Productos
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!