how to create 3-D volume of selected DICOM images ?

7 visualizaciones (últimos 30 días)
yogesh jain
yogesh jain el 12 de Sept. de 2015
Comentada: Walter Roberson el 7 de Mayo de 2018
Hello , I have written a MATLAB code for the operation of converting selected DICOM images into its corresponded 3D volume . But I am not getting any response for longer time as it should complete its execution in limited time . I checked 'mri.mat' and its variable 'D' for reference . Please tell me where i should do correction in my code ? My code is -
clear all
close all
[filename, pathname] = uigetfile( ...
{'*.dcm','DCM Files (*.dcm,)';
'*.dcm', 'DICOM Images (*.dcm)'; ...
'*.*', 'All Files (*.*)'}, ...
'MultiSelect', 'on',...
'Pick file/(s)');
file_len = length(filename);
for i=1:file_len
I{i} = dicomread(filename{i});
Q{i}=imresize(I{i},0.4);
end
II = cell2mat(Q);
AA=uint8(II);
save('new1.mat','II','AA');
load new1.mat;
K = squeeze(AA);
L = padarray(K,[10 10 10],'both');
% Create an isosurface
Ds = smooth3(L);
surface = isosurface(Ds,5);
% Display the surface
hiso = patch('Vertices',surface.vertices,...
'Faces',surface.faces,...
'FaceColor',[.2,.8,.9],...
'EdgeColor','none');
grid on;
view(27,14)
axis tight
daspect([1,1,.35])
lightangle(40,30);
set(gcf,'Renderer','zbuffer'); lighting phong
isonormals(Ds,hiso)
set(hiso,'SpecularColorReflectance',0,'SpecularExponent',50)
Thank you :)

Respuesta aceptada

Walter Roberson
Walter Roberson el 12 de Sept. de 2015
Your code
for i=1:file_len
I{i} = dicomread(filename{i});
Q{i}=imresize(I{i},0.4);
end
II = cell2mat(Q);
is creating II (and therefor the later AA) by concatenating the data long the second dimension. I suspect you wanted to concenate along the third dimension. If so then right before the above for loop insert
Q = cell(1,1,file_len);
Also I do not understand why you later squeeze(AA). Which dimension might be singleton?
When I am reading other people's code, I am more comfortable with them using permute() or reshape() rather than squeeze(), at least if it is not very obvious that one dimension has just been made singleton and the other dimensions are definitely not singleton. When the reader of the code does not know ahead of time what the dimensions of the data are to be, the reader of the code must assume that squeeze() could be operating upon an unexpected dimension, such as if it turned out that the data only had a single row. permute() and reshape() remove the possibility of changing any dimension not explicitly intended to be changed.
  8 comentarios
Ringo Cheung
Ringo Cheung el 7 de Mayo de 2018
In the code, it says that :
Q{i}=imresize(I{i},0.4);
But I am not quite understand why it needs to resize the model by a factor of 0.4, can you briefly explain this?
Thanks, Ringo
Walter Roberson
Walter Roberson el 7 de Mayo de 2018
That imresize() was there in the original, so I presume that the original poster had some good reason for it.