Connecting Resistor and DC Voltage Source
24 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hello, I am trying to connect a DC Voltage Source to four resistors and those resistors to a current measurement and then display this value. Even though the DC Voltage Source and the resistors are all from Simscape, they won't connect. It comes up with a red dotted line and a purple circle. The Current measurement also wont connect to the resistors. I've tried using PS->S and S-> PS converters but this doesn't help either. Any help you can give would be greatly appreciated. Thanks
1 comentario
Sandipkumar Prajapati
el 16 de Mayo de 2021
use both block from Simulink specialization block. Thanks
Respuestas (1)
Sebastian Castro
el 6 de Mayo de 2016
Make sure both of these blocks come from the same block library.
Unfortunately, there are "DC Voltage Source" and "Current Measurement" blocks in both Simscape Foundation and in Simscape Power Systems Specialized Technology libraries.
I'd suggest going to the Simscape > Foundation > Electrical library and grabbing all the blocks from there.
BTW: If you're using one of the latest versions, you can easily tell where they're from because the Simscape blocks will be colored blue whereas the Power Systems ones are not colored.
- Sebastian
5 comentarios
Mahmoud Gamea
el 15 de Mayo de 2021
you can use "ps-simulink" and "simulink-ps" converters for that purpose.
And for a lot of cases I think you will also need a voltage sensor block
.
Comunidades de usuarios
Más respuestas en Power Electronics Control
Ver también
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!