Two Step functions in Different Times , or reset a subsystem block
    13 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
    Safiya
 el 15 de Feb. de 2012
  
    
    
    
    
    Comentada: Stephen23
      
      
 el 28 de Mayo de 2015
            I have a simple model with two Step functions , one enabled subsystem. one step is outside subsystem with a value of 1, and another step is inside the subsystem with value 1. I am monitoring both steps in scope. When i run simulation output becomes 1 at 1 sec in both steps. But I need to do that after first step executes in 1 seconds , the second step inside the block should execute so the output from 2nd step will be 2 secs delayed. (why the both steps execute at the same time , even in enabled-subsystem )
1 comentario
  Stephen23
      
      
 el 28 de Mayo de 2015
				Here is the text of the original question, just in case Safiya decides to delete the text of this question too (like this one):
I have a simple model with two Step functions , one enabled subsystem. one step is outside subsystem with a value of 1, and another step is inside the subsystem with value 1. I am monitoring both steps in scope. When i run simulation output becomes 1 at 1 sec in both steps. But I need to do that after first step executes in 1 seconds , the second step inside the block should execute so the output from 2nd step will be 2 secs delayed. (why the both steps execute at the same time , even in enabled-subsystem )
Respuesta aceptada
  Shiva Arun Kumar
    
 el 15 de Feb. de 2012
        The step time parameter is with reference to the simulation time and not from the time the subsystem is enabled.
For example if you change the step time for source (S1) outside the subsystem to 2sec and retain the step time for the source (S2) within the subsystem at 1 sec you will notice that both signals will transition to 1 at 2 sec.
Similarly if you make the step time of S1 to be 1 and S2 as 2 you will see that S2 will transition to a value of 1 at 2 sec even though the subsystem has been enable at 1 sec. (notice it will not transition to 1 at 3 sec either)
Hope that helps,
3 comentarios
  Shiva Arun Kumar
    
 el 16 de Feb. de 2012
				Hi Haider,
The solution would depend on what you are trying to model in your system and the configuration. For example, if I assume you want the input within your subsystem to transition to 1, one time step after it has been enabled and assuming your sample time is 1, the easiest solution I can think of is to not use a step source within the subsystem. Rather click on the Enable block in your subsystem and check show outport. Connect this outport to delay. This should give the desired result (Assuming that is what you want).
Hope that helps.
Más respuestas (1)
  Kaustubha Govind
    
      
 el 15 de Feb. de 2012
        Perhaps your control signal to the Enabled Subsystem enables it immediately? Make sure that the control signal is enabled only after 2 secs.
Ver también
Categorías
				Más información sobre Target Computer Setup en Help Center y File Exchange.
			
	Productos
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!