What transformer block to use for high frequency operation?

3 visualizaciones (últimos 30 días)
Emmanouela
Emmanouela el 13 de Mzo. de 2012
Comentada: CHANDRA BABU GUTTIKONDA el 16 de Abr. de 2025
Hi! I have a DC-DC Boost Converter with a transformer and 6 switches with high switching frequency at Fs=35KHz. Do these blocks for transformers support this operation in simullink as the results obtained show the output frequency of the secondary winding of the transformer to take the desired value simultaneously and afterwords to be decreased I guess due to losses. Do you know how the output voltage could remain in this value constant during the simulation time? Is there any other block for a transformer that could be used without any losses? Thanks a lot in advance!
Emmanouela
  5 comentarios
Jyotiprakash
Jyotiprakash el 11 de Mzo. de 2025
did you find any kind of solution for this
CHANDRA BABU GUTTIKONDA
CHANDRA BABU GUTTIKONDA el 16 de Abr. de 2025
Reduce winding resistances and magnetizing inductance losses to near-zero manually in block parameters for linear transformers

Iniciar sesión para comentar.

Respuestas (1)

DEBASISH MISHRA
DEBASISH MISHRA el 31 de Dic. de 2017
calculate the value of Lm, L1 and L2 in a saturable transformer simulink library.Then apply the same to replicate it as a high frequency transformer
  2 comentarios
Jyotiprakash
Jyotiprakash el 11 de Mzo. de 2025
but there is no part where to add Lm. and will you tell to calculate all depending upon its hardware parts

Iniciar sesión para comentar.

Etiquetas

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!