How to calculate energy usage from the Refrigeration Cycle model in Simscape?
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Ambareesh Rathi
el 18 de Mzo. de 2017
Respondida: Alisha Schor
el 21 de Mzo. de 2017
In the Simscape's Refrigeration Cycle model (ssc_refrigeration), I would like to determine/calculate energy usage when a cycle is simulated in Simulink.
Any leads would be appreciated. Thank you!
0 comentarios
Respuesta aceptada
Alisha Schor
el 21 de Mzo. de 2017
Simscape signal logging is a good place to start. This will give you access to all of the physical variables associated with each component. By probing values of the the various blocks, you can calculate the values of interest.
As a template, you can open the source code for the first embedded link in the model, "Plot performance of system." Here you can see, that compressor power, for example, can be accessed by the command:
simlog_ssc_refrigeration.Compressor.Controlled_Mass_Flow_Rate_Source_2P.power.series.values('W');
and that this is used to calculate and display the instantaneous power of the compressor. You could then integrate this value over the course of the simulation to determine the total energy input to the compressor. Following this same concept, one can also calculate the total heat energies and the expansion energy by probing the appropriate quantity.
0 comentarios
Más respuestas (0)
Ver también
Categorías
Más información sobre Simscape Fluids en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!