Simulink coder doesn't generate custom storage class code?

With the attached model and data dictionary, the generated code still put the parameter p1 in its default header file, although I specified it as custom storage class and should be "ConstVolatile".
What did I miss in the configuration?
Thanks

 Respuesta aceptada

Song
Song el 12 de Mayo de 2017
change from grt to ert solves this problem.