Accuracy in Simulink in transient process calculation

1 visualización (últimos 30 días)
Hi,
I try calculate current in scheme (figure below).
There are some commutations:
1) t < 0, brA is off, brA1 is on;
2) t = t0, brA1 switch off;
3) t = t1, brA switch on.
Current in brA shown on figure below.
Where is problem? Why current amplitude isn't tend to steady state value?
Some additions:
EMTP doesn't have this problem and return right current curve.
All solvers give similar results.

Respuesta aceptada

Joel Van Sickel
Joel Van Sickel el 16 de Sept. de 2020
Hello Sergey,
for specialized power systesm, we recommend that you use solver ode23tb. You mention that you get the same results regardless of solver. This transient looks like ringing that could genuinely be there because of the inductances and capacitances in your model. You would need to provide a full schematic of the EMTP and simulink model to make a comparison before determining if anything is wrong. It is most likely that this circuit is not actually set up the same as the EMTP circuit and that both tools are simulating correctly for the data that was entered into them. Transferring a circuit from one simulator to another can often lead to unforseen differences because not all parameters are specified the same and similar blocks may behave differently than you expect. The most likely block to be causing problems would be the PI transmission line. After that, i would check the load block.
Regards,
Joel

Más respuestas (0)

Categorías

Más información sobre Magnetic Elements en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by