Borrar filtros
Borrar filtros

Simulink Design Verifier Dead Logic

1 visualización (últimos 30 días)
Man Sun
Man Sun el 29 de Mayo de 2017
Respondida: Nikhilesh el 18 de En. de 2023
I have recently used simulink design verifier to check my state machine model. And some dead logics are detected. But in fact this dead logic is resulted from the execution order. Here is an example: State A is active when transition 1 [a>20] is true, State B is active when transition 2 [a<=20] is active. And the execution order is that first the transition 1 will be checked and then transition 2. My Simulink Design Verifier told me that transition 2 can not be false. The reason behind is that every time when a>20 the transition 1 will be firstly checked and fulfilled. The system goes directly in state A. So the transition 2 will not be checked.
Now the model should be optimized to avoid this error detection with Design Verifier. Has anybody ideas?
  2 comentarios
Pat Canny
Pat Canny el 16 de Mayo de 2018
What is the possible range of values for your variable a?
galaxy
galaxy el 14 de Nov. de 2019
Yes, I have same problem.
8.PNG
Red line is dead logic, data type of input1 and input2 are int16.
Could you please explain to me??

Iniciar sesión para comentar.