I am trying to delay the input of an analog reading so that it only reads every 10 seconds, while the rest of the program still runs. I tried the variable time delay but that didn't give me the result I wanted (although it is possible I am using it incorrectly). Any ideas? I don't want to delay the entire model, just this one input.
Respuestas (1)
Brian Hannan
el 17 de Ag. de 2017
0 votos
You can use a Sample and Hold block for this. Or you can create a trigger signal with a 10-sec. period to drive a simple enabled subsystem that just passes its input signal value.