Executing Stopfcn model callback

10 visualizaciones (últimos 30 días)
Karl Neuhold
Karl Neuhold el 21 de Ag. de 2017
Respondida: Aniruddha Katre el 22 de Ag. de 2017
Hello!
When is the stopfcn callback (model callback) executed? I start the model: sim (...); exit force;
I can not find information in the documentation.
thanks Karl

Respuesta aceptada

Aniruddha Katre
Aniruddha Katre el 22 de Ag. de 2017
See the section called Model Simulation Callback Parameters.
The StopFcn callback will execute when a simulation stops by either running to completion or is stopped by the user.
When you use exit, that is simply going to close MATLAB entirely and the execution of the StopFcn callback is a moot point.
Try a simple test:
In a models StopFcn callback define a variable such as x = 10. Then run the simulation using sim or just pressing the simulate button. When the simulation runs to completion, the variable x should be defined in the workspace.

Más respuestas (0)

Categorías

Más información sobre Model, Block, and Port Callbacks en Help Center y File Exchange.