Borrar filtros
Borrar filtros

Simulink Test baseline data from excel

9 visualizaciones (últimos 30 días)
Pawel Kajak
Pawel Kajak el 5 de Oct. de 2017
Respondida: haotian zhang el 8 de Mzo. de 2019
I'm having a problem with using data from an Excel sheet within my example baseline test in Simulink. The test fails with Baseline Criteria Result of "Signal did not align". Can you give me any clue on what might be the problem here. All files in attachment. Thanks.

Respuesta aceptada

Abhishek
Abhishek el 17 de Nov. de 2017
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what the simulation is producing. The other way could be to log the output signal. The root cause is the extra ":1" which gets added for Output ports.

Más respuestas (2)

haotian zhang
haotian zhang el 8 de Mzo. de 2019
I have the same problem. Change "Out1" to "Out1:1" solves the problem

haotian zhang
haotian zhang el 8 de Mzo. de 2019
Thanks

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by