Simulink Test baseline data from excel
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Pawel Kajak
el 5 de Oct. de 2017
Respondida: haotian zhang
el 8 de Mzo. de 2019
I'm having a problem with using data from an Excel sheet within my example baseline test in Simulink. The test fails with Baseline Criteria Result of "Signal did not align". Can you give me any clue on what might be the problem here. All files in attachment. Thanks.
0 comentarios
Respuesta aceptada
Abhishek
el 17 de Nov. de 2017
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what the simulation is producing. The other way could be to log the output signal. The root cause is the extra ":1" which gets added for Output ports.
0 comentarios
Más respuestas (2)
haotian zhang
el 8 de Mzo. de 2019
I have the same problem. Change "Out1" to "Out1:1" solves the problem