Simulink Test customCriteria - structRefFromNonStruct error
10 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I am logging the data to monitor the active step of Test sequence block to workspace. I tried to use this logged data in CustomCriteria function using the following code.
data = test.sltest_simout.get('logsout').get('state').Values.Data(end);
and it returns the following error.The type of data is 'Enum:Test_Sequence_Active_Step_Enum'. What might be the problem? I had attached the logsout workspace file.
-------------------------------------------------------------------- Error occurred in custom criteria and custom criteria assessment did not run to completion.
---------
Error ID:
---------
MATLAB:structRefFromNonStruct
--------------
Error Details:
--------------
Struct contents reference from a non-struct array object.
--------------------------------------------------------------------
1 comentario
Khoo Yit Phang
el 13 de Dic. de 2017
Hi,
Do you mind attaching your model and mldatx test file? It would give me a better idea about what's going on. Also, which version of Simulink are you running?
Thanks,
Yit
Respuestas (0)