Reset in FilterHDL RTL code

1 visualización (últimos 30 días)
Davide Capotosto
Davide Capotosto el 26 de En. de 2018
Comentada: Davide Capotosto el 2 de Feb. de 2018
Hello, I would like, when generating RTL code from Filter HDL coder toolbox, to create code with both asynchronous and synchronous resets. Is it possible ? How ? Many thanks in advance

Respuestas (1)

Gaurav Phatnani
Gaurav Phatnani el 2 de Feb. de 2018
Hi Davide,
Unfortunately there is no way to generate code for both Asynchronous and Synchronous Reset Types by calling code generation once. In order to do this you will have to run code generation two times.
You can write a MATLAB script to automate this process. This link has some documentation on the Command Line Interface for HDL code generation.
To change the 'ResetType' from a MATLAB script you can use the following function:
>> hdlset_param(gcs,'ResetType','sync') %change the Reset Type to Synchronous
>> hdlset_param(gcs,'ResetType','async') %change the Reset Type to Asynchronous
  1 comentario
Davide Capotosto
Davide Capotosto el 2 de Feb. de 2018
Good afternoon, but if I launch code generation 2 times I will get 2 different codes, one with asynchronous and one with synchronous reset, am I right ? what I was expecting was a method to obtain one piece of code with the 2 reset istantianted. Something like always @(posedge clock or posedge reset_async) begin if (reset_async==1) pdm_data_resampled <=0; else begin if (reset_sync==1) pdm_data_resampled<=0; else begin ..... end
with 2 different codes, the "merge" can be very tedious . Best Regards