Hello ! I do have the following problem: I have a very big simuling model, with a lot of subsystems. In this model a lot of signal have already logged. I'm making a test environment to run this model, and I have to test the result of the simulation. I have to log only a few data, but in the model there are approximately 150 logged signal (and it's made the simulation much slower). So for that, in my test environment I'd like to unlog all of the signal, and turn on only witch are necessary for me.
Respuesta aceptada
Más respuestas (2)
Paul Smith
el 31 de En. de 2019
4 votos
I had a similar issue, I ended up modifying to this though:-
pH = find_system('Your Model name','LookUnderMasks','all','FindAll', 'on', 'DataLogging', 'on');
'Type', 'Port'
Having type and port in the search misses other potentially logable terms.
Zhu
el 26 de Jul. de 2019
0 votos
Turn this model into .mdl format
Open model in text
Find all "datalogging on", set it to off
Done!
3 comentarios
Jun Yang
el 20 de Nov. de 2023
this command works in a better way!
set_param(bdroot, 'InstrumentedSignals', [])
Herman Wong
el 7 de Mzo. de 2024
Editada: Herman Wong
el 7 de Mzo. de 2024
set_param(bdroot, 'InstrumentedSignals', []) --- awesome! Thanks Jun Yang!
Jinggang
el 9 de Jul. de 2024
Thank u Jun Tang, it works!