Automatically rename external Output in generated C-Code
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hello community, I am using the embedded coder in Matlab 2017b to generate code from my Simulink models. My problem is that I have multiple Simulink models and I want to generate code for each of them seperatly. Unfortunately the embedded coder labels the external structure for each model the same. Therefore, when I include the header and source files from the generated code I get redefinitions. Is there any way to automatically rename these external structures?
extern ExtU rtU
extern ExtY rtY
Thank You
0 comentarios
Respuestas (1)
Vineeth Nair
el 14 de Sept. de 2018
I am not exactly sure, what you mean by external structure. If you are asking about the external output ports, which are defined in a structure in the header file, then you can rename these output ports in the Simulink model. By default they are named as Out1, Out2, etc. Also to rename other variables generated by code generator, In model configuration parameters, Under code generation, there is option called Symbols. You can rename various variables and methods here.
0 comentarios
Ver también
Categorías
Más información sobre Simulink Coder en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!