As stated in Design Your Model for Effective Acceleration, Simulink does not allow the update of scope unless the rapid accelerator model is run from Simulink menu, for whatever reason. However, I am using a GUI to call the Simulink model and I wish to see real-time output using the scope, but the scopes won't update.
I wonder if there is a way to change this Simulink behaviour (this restriction really seems artificial to me). Alternatively, I wonder if there is a way to pretend (using command line code) that I am running the model from Simulink menu.
0 comentarios
Respuesta aceptada
TAB
el 5 de Oct. de 2018
Editada: TAB
el 5 de Oct. de 2018
Scope will not update with sim command, but it works with SimulationCommand (please dont ask why :P)
set_param('MyModel', 'SimulationCommand', 'start')
SimulationCommand can take one of following value:
'start' | 'stop' | 'pause' | 'continue' | 'step' | 'update' | 'WriteDataLogs' | 'SimParamDialog' | 'connect' | 'disconnect' | 'WriteExtModeParamVect' | 'AccelBuild'
3 comentarios
TAB
el 5 de Oct. de 2018
You can use get_param('mymodel', 'SimulationStatus') combined with while loop to wait for simulation to finish.
Más respuestas (1)
Qiaoli Ji
el 19 de Dic. de 2018
Hi, Kaixiang Wang , I have met a question about matlab compiler installation. So could you help me? Thanks
QQ:1069994175
0 comentarios