how to solve this problem
11 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
An error occurred while running the simulation and the simulation was terminated
For block 'PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch', control port value '0' is not in between '1' and '6'. To suppress this message and use the default port, you can change the settings of 'Diagnostic for default case' to 'None'
Component: Simulink | Category: Block error
2 comentarios
Walter Roberson
el 4 de Mzo. de 2019
Either figure out why the control port was 0, or else make the change they suggest.
Sai kartheek Chavali
el 4 de Mzo. de 2019
PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch
what is the model functionality?
Respuestas (1)
Sabin
el 5 de Jun. de 2025
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a multiport switch that is 0 but the parameter 'Data port order' is set to One-based contiguous (this means that the out of range condition is: the control input is less than 1 or greater than the number of data inputs.).
0 comentarios
Ver también
Categorías
Más información sobre Electrical Block Libraries en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!