How to make a gate valve work in a hydraulic circuit?

1 visualización (últimos 30 días)
Austin Purvis
Austin Purvis el 18 de Jun. de 2019
Respondida: Juan Sagarduy el 1 de Dic. de 2020
I am having trouble connecting a Gate Valve block to my hydraulic circuit. The hydraulic circuit uses a constant pressure source and passes flow through a 4-way directional valve to a motor (not pictured). I want to add a gate valve after the directional valve so that I can proportionally restrict flow.
The pipe is 19mm in diameter, however the constant signal that is being passed into the gate valve is 9 becuase I want to restrict the flow about 50%.
The pressure sensors before and after the gate valve indicate that there is no change in the flow. How do I fix this issue, so that the gate valve will proportionally restrict flow when I feed in different values?
  1 comentario
omkar tulankar
omkar tulankar el 27 de Nov. de 2020
Hi ,
I am also trying to use gate valve in gas system to delay the flow of gas flow in the circuit.
What I intend to do is start the gas flow between two ports in the circuit after the defined time delay with the help of valve .
But there's no effect seen on the output end.
I would like to know if there's any possible solution to this , "using gate valeve is gas systems ".
Thanks

Iniciar sesión para comentar.

Respuestas (1)

Juan Sagarduy
Juan Sagarduy el 1 de Dic. de 2020
Hi there Have you checked that the unit in the S-PS converter for the gate valve is set to mm? If not, Simscape believes it is 9m which is fully opening all the time. Br Juan