Weird issue with Simulink model

10 visualizaciones (últimos 30 días)
Lucas
Lucas el 28 de Ag. de 2012
At work I’m working with a new version of the model that I’ve been working with. In the previous version of the model I haven’t had any problems at all, but now I’m running into a weird one right now.
If I open the model, do a search (find) on the model with a name, I only get one result. But if I type:
find_system('FindAll', 'on', 'Name', 'VariableName')
it return multiple instances of the name. This causes my tool to do not work properly. Has anyone seen an instance where find returns a number of instances but find_system returns a different number. All the instances of the handles I got from find_system are centered around the single instance returned from find.

Respuesta aceptada

Albert Yam
Albert Yam el 28 de Ag. de 2012
Editada: Albert Yam el 28 de Ag. de 2012
find_system(gcs,'FindAll', 'on', 'Name', 'VariableName') %needed a sys
I've never used the edit > find, but when I used find_system, something about finding the subsystem (or root) name of what you are centered on (rather than just everything inside the subsystem). But I don't think that is your problem.
Just did a little test. [const,line,scope] all named. The find_system, found the PORT, and the signal, the edit>find, only found the signal.
Suggest, add BlockType as a parameter.
What Simulink are you using? [6.6.1 here]
EDIT:
>> sx = find_system(gcs,'FindAll', 'on', 'Name', 'sigx')
sx =
1.0e+003 *
1.8550
0.0180
>> set_param(sx(1),'null','1')
??? Error using ==> set_param
port does not have a parameter named 'null'.
>> set_param(sx(2),'null','1')
??? Error using ==> set_param
line does not have a parameter named 'null'.
  7 comentarios
Albert Yam
Albert Yam el 29 de Ag. de 2012
Editada: Albert Yam el 29 de Ag. de 2012
It is because you have another model or reference library open. I made a reference to the answer when I tested it with Simulink browser and Constant.
Try this as an example, open a new model, open a second new model, open the Simulink browser. Copy a block, say Cosine to the 2 open models. Don't close any model.
Now find_system('FindAll', 'on', 'Name', 'Cosine') will give 3 results, but edit/find will give one.
Edit: Meaning, if you do not define a 'sys' in the find_system, it searches all models open, not just the highlighted one.
Albert Yam
Albert Yam el 29 de Ag. de 2012
Hm.. are you sure that your script, or some callback isn't open_system/load_system anything? I wonder if there is a way to see what systems are open/loaded. I don't know how model referencing works, I'm wondering if it has some affect if it is referenced more than once.
By 6 instances, you just mean 6 windows open right? You can close 5 of them and save, next time you open it should just be the one (or specifically choose what you want to open), just for convenience though.

Iniciar sesión para comentar.