Simulink trying to map struct to run-time parameter

20 visualizaciones (últimos 30 días)
Marshall Trout
Marshall Trout el 21 de Ag. de 2019
Respondida: Noah Tang el 28 de Sept. de 2021
When attempting to run a function inside a Simulink model the simulation always fails due to the following error:
Unable to map parameter 'VarName' in 'FunctionName' to a run-time parameter. This parameter is an unsupported variable class such as a string, structure, cell, or an unsupported data type.
VarName is indeed a struct, but I do not understand why Simulink is attempting to make it a run-time parameter. VarName contains the initial conditions and online parameters used throughout the simulation. The Simulink model was built in 2013a and I am attempting to update it to run in 2017b. How can I prevent this error from occuring?
Thanks in advance.

Respuesta aceptada

Marshall Trout
Marshall Trout el 26 de Ag. de 2019
Unsure what the actual cause was, but a windows update seems to have cleared up the error.
  2 comentarios
Toheed Ghandriz
Toheed Ghandriz el 26 de Sept. de 2019
I got the same error but it was solved after removing the check mark in front of 'Tunable' in Edit data dialog box for 'VarName'. My VarName was structure too.

Iniciar sesión para comentar.

Más respuestas (1)

Noah Tang
Noah Tang el 28 de Sept. de 2021
I was able to reproduce the same error message, and the comparison shows that the error happens when one field of my struct variable has an empty array as its value. Otherwise, the parameter passing process works just fine.

Categorías

Más información sobre Configure and View Diagnostics en Help Center y File Exchange.

Productos


Versión

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by