Step size error when simulating with SimPowerSystems

1 visualización (últimos 30 días)
arvind
arvind el 27 de En. de 2011
I have a design and simulated it using Simulink. Its components belong to the SimPowerSystems blocks. When I am simulating it, I get an error and the simulation halts in the middle. The error message reads
unable to reduce step size without violating a step size of 7.3834....e-17 at 0.2034... s
I tried changing the relative tolerance in the configuration parameters, that did not work.
I am using ODE23t as my solver.

Respuesta aceptada

Sebastian
Sebastian el 27 de En. de 2011
The "Choosing an Integration Algorithm" section of the SimPowerSystems documentation contains some hints on which solver parameters to tweak, in particular if switches and Power Electronics devices are in the model: http://www.mathworks.com/access/helpdesk/help/toolbox/physmod/powersys/ug/f7-7663.html#f7-7664
  1 comentario
Todd Flanagan
Todd Flanagan el 28 de En. de 2011
Arvind says, "Thank you. I had to tweak a few parameters in the solver configuration parameters and make minor changes in my circuit component values and it worked. I also changed the solver to Ode23tb instead of Ode23t."