Step size error when simulating with SimPowerSystems
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
I have a design and simulated it using Simulink. Its components belong to the SimPowerSystems blocks. When I am simulating it, I get an error and the simulation halts in the middle. The error message reads
unable to reduce step size without violating a step size of 7.3834....e-17 at 0.2034... s
I tried changing the relative tolerance in the configuration parameters, that did not work.
0 comentarios
Respuesta aceptada
Sebastian
el 27 de En. de 2011
The "Choosing an Integration Algorithm" section of the SimPowerSystems documentation contains some hints on which solver parameters to tweak, in particular if switches and Power Electronics devices are in the model: http://www.mathworks.com/access/helpdesk/help/toolbox/physmod/powersys/ug/f7-7663.html#f7-7664
1 comentario
Todd Flanagan
el 28 de En. de 2011
Arvind says, "Thank you. I had to tweak a few parameters in the solver configuration parameters and make minor changes in my circuit component values and it worked. I also changed the solver to Ode23tb instead of Ode23t."
Más respuestas (0)
Ver también
Categorías
Más información sobre Electrical Sensors en Help Center y File Exchange.
Productos
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!