Retaining previously held values in simulink
11 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I have a simulink model that is run using a code in a loop in consecutive time-steps. However, there's a problem, that the model resets itself before each new time-step (loop). I was wondering if there is an option for the model to NOT RESET itself before new iteration, in other words, I want all signals to keep (retain) their last held values from previous iteration. Thanks.
0 comentarios
Respuestas (1)
Jonas
el 13 de Feb. de 2020
Editada: Jonas
el 13 de Feb. de 2020
It is not completely clear to me what your set-up looks like, but you may want to investigate 'Enabled Subsystems'. You can set each output to be 'held' or 'reset' when enabling.
2 comentarios
Jonas
el 14 de Feb. de 2020
I assume that each iteration you do, is running the simulation model, stopping it, and starting it from stratch. What I would do is put the part that you want to iterate inside an Enabled Subsystem but the plant model not. Then you could enable and reset the iterative part that you DO want to reset with a certain clock or trigger. The plant model however just keeps running.
This means that instead of running, stopping and restarting your whole Simulink model, you run it once.
Hope this is somewhat clear and inspiring.