Hi,
I have a Simulink block that sets PWM frequency. The things is that the PWM frequency must be the invert of the Simulink step size. I would like to adjust the step size of my Simulink project automatically everytime I modify the PWM frequency. The PWM frequency is set in the mask of my Simulink Block. How should I proceed?
Regards

Respuestas (1)

Jesús Zambrano
Jesús Zambrano el 27 de Mzo. de 2020
From what I understand, you would like to change the step size of the Solver during time. Step size, as well as other parameters such as sample time are nontunable parameter of the model. The new value will not be used in the current simulation. You need to restart the simulation if you would like to use the new value.
  1 comentario
Benjamin Couillard
Benjamin Couillard el 30 de Mzo. de 2020
I want to insure consistency between PWM frequency and sampling time as the relation between the 2 must be "locked". For example a PWM frequency of 1 kHz means the the discrete step size must be 1 ms or 500 µs. I found a way to do it in the Init Function of my custom Simulink block. Perhaps not the best solution, but it works well so far.