Why have some bus signals wrong datatypes?
16 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hello,
I have the problem that at the inport and outports of some bus creators/selectors there are wrong datatypes (and though the model is not compileable). I get the following error message:
Data type mismatch. Input port 1 of '<BusCreator>' expects a signal of data type 'single'. However, it is driven by a signal of data type 'double'.
and
Data type mismatch. Output port 1 of '<Subsystem>' is a signal of data type 'double'. However, it is driving a signal of data type 'single'.
As you can see e.g. the output datatype of the top signal ("DrvResis_fVehMEstimNum") is double but the input datatype to the bus creator is single.

But the datatype of the input to other subsystems is also double.

So how can this be? Shouldn't the datatype be fixed through the inputs/outputs of the subsystems?
Thank you very much in advance.
0 comentarios
Respuestas (1)
Mark McBroom
el 4 de Abr. de 2020
Did you specify a Simulink Bus in the Bus Creator dialog? If so, then the signals feeding the bus creator must match the types defined in the Simulink Bus.
2 comentarios
Jorge Castillo
el 30 de Jul. de 2024
Hello Pascal,
Have you get any answer from Mathworks regarding this topic?
Ver también
Categorías
Más información sobre Load Signal Data for Simulation en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!
