Borrar filtros
Borrar filtros

Buffer size warning in simulink

129 visualizaciones (últimos 30 días)
Ahmed Rehan
Ahmed Rehan el 14 de Abr. de 2020
Comentada: ali ebrahim el 6 de Jun. de 2023
Hello,
I am running a search code with using fminearch. The function that fminsearch calls runs simulink to generate a final output where in Simulink I am running a control system simulation (figure below). Now the question is I am getting this warning multiple times, and I am not sure if this affects the final result or not:
Warning: The specified buffer for 'MRFT_2param_optim/Delay' was too small.During simulation, the buffer size was temporarily increased to 2048. In order to generate code, you need to update the buffer size parameter
  5 comentarios
Ahmed Rehan
Ahmed Rehan el 14 de Abr. de 2020
I see..
ali ebrahim
ali ebrahim el 6 de Jun. de 2023
you need to click the ling of the buffer to see what block have this problem after that you are going to block setting to adjust the sample time to 1

Iniciar sesión para comentar.

Respuestas (1)

Chidvi Modala
Chidvi Modala el 29 de En. de 2021
The delay block fills up a buffer with samples until it reaches a duration of one time delay specified by the block parameter. Once this is done, it will begin outputting the signal.
If the sample time was very small and the time delay was relatively large, then Simulink may need to re-size the buffer in order to hold one time delay. While Simulink can perform this operation, the generated code must use fixed buffer sizes and cannot perform this without using a bigger buffer
  2 comentarios
Sebastian Gast
Sebastian Gast el 28 de Abr. de 2021
Thank you for the explanation.
could you tell how one can increase the buffer before starting the simulation?
Sam Stringer
Sam Stringer el 30 de Ag. de 2021
Also keen to know this

Iniciar sesión para comentar.