Simulink MPC Controller Constraints

6 visualizaciones (últimos 30 días)
James Hughes
James Hughes el 19 de Abr. de 2020
Comentada: James Hughes el 22 de Abr. de 2020
I am designing an MPC controller in Simulink, the plant has 3 manipulated inputs and 2 controlled variables.
The plant also has 4 additional measured variables which I would like to use as constraints. My question is, how do I make the measured constraints available to the MPC controller? Do I need to make them controlled variables and give them a nominal reference?

Respuesta aceptada

Emmanouil Tzorakoleftherakis
Emmanouil Tzorakoleftherakis el 21 de Abr. de 2020
Hi James,
By "controlled variables" I am assuming you are referring to measured outputs. I believe that with linear MPC you can only specify constraints on measured outputs, so the 4 additional variables you mentioned should be converted to measured outputs.
With nonlinear MPC you can set constraints to both outputs and states.
  1 comentario
James Hughes
James Hughes el 22 de Abr. de 2020
Thank you very much for your clear answer

Iniciar sesión para comentar.