Simulink MPC Controller Constraints
6 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
James Hughes
el 19 de Abr. de 2020
Comentada: James Hughes
el 22 de Abr. de 2020
I am designing an MPC controller in Simulink, the plant has 3 manipulated inputs and 2 controlled variables.
The plant also has 4 additional measured variables which I would like to use as constraints. My question is, how do I make the measured constraints available to the MPC controller? Do I need to make them controlled variables and give them a nominal reference?

0 comentarios
Respuesta aceptada
Emmanouil Tzorakoleftherakis
el 21 de Abr. de 2020
Hi James,
By "controlled variables" I am assuming you are referring to measured outputs. I believe that with linear MPC you can only specify constraints on measured outputs, so the 4 additional variables you mentioned should be converted to measured outputs.
With nonlinear MPC you can set constraints to both outputs and states.
Más respuestas (0)
Ver también
Categorías
Más información sobre Controller Creation en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!