How to set parameters of Recursive Polynomial Model Estimator in Simulink

2 visualizaciones (últimos 30 días)
Hello! everyone,
I have a question when using the Recursive Polynomial Model Estimator. I am trying to achieve the online estimation of a two-input two-output system. So my settings are na: [2,2;2,2], nb: [1,1;1,1]; nk: [1,1;1,1]. But there is an error that shows the number of parameters in na must be a scalar. Why is there such an error? How to fix it?
Thanks.

Respuesta aceptada

Rajiv Singh
Rajiv Singh el 8 de Jul. de 2020
The Recursive Polynomial Model Estimator supports single output estimations only.
  5 comentarios
Rajiv Singh
Rajiv Singh el 9 de Jul. de 2020
The recursive estimation features are limited right now and we plan to remove I/O size limitations in future. Right now, one possibility is to use a different estimator for each output. If you have multiple inputs too, you can only use the ARX recursive estimator.

Iniciar sesión para comentar.

Más respuestas (0)

Categorías

Más información sobre Linear Model Identification en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by