Request to help in sorting an error in simulink

2 visualizaciones (últimos 30 días)
SANTOSH
SANTOSH el 21 de En. de 2013
Hi in my project while transferring data from 1 functional block to another i encountered the below error, where if i run the code in matlab err1 has data but if i run in simulink it is displaying following error please help me Thanks in advance
"Inferred size for data 'err1' (#59) is empty, which is invalid for a Simulink signal."
  1 comentario
Kaustubha Govind
Kaustubha Govind el 21 de En. de 2013
I'm assuming this is in a MATLAB Function block? How does your MATLAB code in the block define 'err1'?

Iniciar sesión para comentar.

Respuesta aceptada

Walter Roberson
Walter Roberson el 21 de En. de 2013
You could get that if your code builds up "err1" dynamically, something like
err1 = [];
for K = 1 : 10
err1 = [err1 K];
end
Instead you should allocate err1 as the maximum size immediately on the first assignment to it. I seem to recall that you can reduce the size later, but not increase it.