Is there any Steady-state error for Step input command?
107 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
clear all
clc
syms s;
K=1;
Gnum=(50/3)*K;
Gden=sym2poly((s+5)*(s+(10/3))*(s+1));
G=tf(Gnum,Gden);
Hnum=20;
Hden=sym2poly(s+20);
H=tf(Hnum,Hden);
figure
rlocus(G*H*K);
T=feedback(G*K,H);
figure
step(T)
figure
rlocus(T)
0 comentarios
Respuestas (1)
Nagasai Bharat
el 19 de En. de 2021
Editada: Nagasai Bharat
el 19 de En. de 2021
Hi,
From my understanding you are trying to find the Steady state error(SSE) for the step response. Steady state error is the absolute difference between the actual value and the desired value at the steady state i.e assuming the end of the plot in this case. SSE is meaningless for unstable closed loop systems.
Desired value appears to be 0.5 from the plot.
To get the SSE
[y,t] = step(T);
sse = abs(0.5 - y(end));