PMSM (simscape) No load test
6 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hey guys,
I am trying to resolve my no load data out of my in simscape designed PMSM.
With load it is no problem and the motor is working properly. I am using a ideal torque source for my load simulation.
But when I type in 0 the motor is not working properly.
So how can I do a no load test with the PMSM.
A open circuit is not the right thing at this place because it uses high (inf) resistances and I am not able to get my no load current.
Maybe one of u tried this before... I hope so.
Best regards and thanks in advance.
3 comentarios
Federico Manfrin
el 15 de Abr. de 2021
I think you're using the PMSM as voltage/current generator, right?
Respuestas (1)
Joel Van Sickel
el 17 de Ag. de 2021
If you are using specialized power systems, it can be very hard to model a no-load test without very small time steps. It might make more sense to use the simscape components (blue components) to model this. You can also use a large snubber resistor to get "almost" no load current. Esentially, the smaller your time step, or the lower your resistance, the easier it will be to get a value.