Process raw data using lowpass filter
    11 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
    nam bui
 el 10 de Feb. de 2021
  
    
    
    
    
    Comentada: Rahim Nami
 el 13 de Oct. de 2022
            Hi,
I have a excel file with raw data containg 1200 rows and 2 columns named A and B. I'm try to apply a lowpass filter on the signal but looks like its not working, hopefully someone on here may have time to guide me to the right direction. 
here is what I did so far:
imported data as a table -> created a script -> inside of the script -> load rawdata.csv 
% sampling frequency [Hz]
Fs = 1000;
% sampling period [s]
Ts = 1/Fs;
% time vector [s]
t = 0:Ts:3;
% Signal A 
sig_A = rawdata(:,1);
% Signal A 
sig_B = rawdata(:,2);
order = 4;
fcut = 8000;
[sig_A,sig_B] = butter(order,fcut/(fs/2),'low');
x = filter(sig_A,sig_B);
0 comentarios
Respuesta aceptada
  Alberto Mora
      
 el 10 de Feb. de 2021
        
      Editada: Alberto Mora
      
 el 10 de Feb. de 2021
  
      You are confusing the filter coefficient with the raw signal.
Try this:
[b,a] = butter(order,fcut/(fs/2),'low');
sig_a_filt = filter(b, a, sig_A );
5 comentarios
  Rahim Nami
 el 13 de Oct. de 2022
				Hi everyone
Please, mathematical formula or mathematical model of the codes used. you insert
thank you
r_nami@gmx.com
Más respuestas (0)
Ver también
Categorías
				Más información sobre Signal Modeling en Help Center y File Exchange.
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!