Signal Time Range-SIMULINK

I want my input signal only two run for a specific time say from [5 sec to 20 secs ] when my simulation time is 100 secs,, is there any way to do this

Respuestas (1)

Pavan Guntha
Pavan Guntha el 25 de Mzo. de 2021

0 votos

You may try to solve using the following steps:
1) Use clock block to get the current simulation time.
2) Append a combinational logic to actually compare current simulation time with your time of interest.
3) Use an enabled subsystem to appropriately route the signal to output with output signal of step 2 as control signal to this block.
Here's an illustration of these steps:
As depicted in the scope, the signal (here sine signal is taken as an example) is routed to the output only in the time slot of interest.

2 comentarios

NIHAD MOHAMED ALI
NIHAD MOHAMED ALI el 27 de Mzo. de 2021
how do i invoke this >=5 or <=20 blocks?
Pavan Guntha
Pavan Guntha el 29 de Mzo. de 2021
You can refer to the compare to constant block documentation for more details.