Initial value and time delay SIMULINK
5 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Karl Persson
el 17 de Mzo. de 2021
Comentada: Karl Persson
el 23 de Mzo. de 2021
Hi!
I have a system that im trying to create a controller for but I can't make a good model in SIMULINK.
The system looks like the one I drawn below and the output signal should look something like the plot I've drawn. However I can't make the initial value and the time delay work at the same time. Eather I get a system with 0 time delay and with the right initial value or I get a system with 0.5s time delay and 0 as its initial value.
How should I make this system in SIMULINK.
The system is in continious time.
Thanks,
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/553442/image.png)
0 comentarios
Respuesta aceptada
Kiran Felix Robert
el 23 de Mzo. de 2021
Hi Karl,
As your System is in continuous time,you can utilize the Transport Delay Block and the Transfer Fcn with initial outputs block (in Simulink extras) to model the initial output and the Time delay.
Or,
In order to provide the initial condition for transfer function you can convert it to its controllable canonical state-space (tf2ss) form then use the state-space block. Refer this documentation page.
Más respuestas (0)
Ver también
Categorías
Más información sobre Dynamic System Models en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!