PMSM Simscape Block - Inertia mask parameter

1 visualización (últimos 30 días)
Giovanni Pizzolante
Giovanni Pizzolante el 12 de Abr. de 2021
Movida: Sabin el 24 de Dic. de 2022
Hi all! :)
I have a doubt about a mask parameter to be set in the following Simscape block (https://it.mathworks.com/help/physmod/sps/powersys/ref/permanentmagnetsynchronousmachine.html). The parameter to be set is the Combined machine and load inertia coefficient J (kg.m2) and I was wondering if it should be set considering the size as motor side or load side? It is not specified anywhere.
In particular, the rotor has its own inertia J_rotor and also an Harmonic Drive (transmission ratio k> 1) is attached to the motor, which has its own inertia J_HarmonicDrive (defined at the harmonic drive input side). I was wondering how the J mask parameter should be set. Should I pass J = J_rotor + J_HarmonicDrive (i.e. sum of motor side inertias) or J = (J_rotor + J_HarmonicDrive) / k ^ 2 (i.e. sum of load side inertias)?
Thanks!

Respuesta aceptada

Dakai Hu
Dakai Hu el 22 de Abr. de 2021
Movida: Sabin el 24 de Dic. de 2022
Hi Giovanni,
In this case, if you can figure out what J_HarmonicDrive is, I'd use J = J_rotor + J_HarmonicDrive as the inertia parameter for the PMSM block.
  3 comentarios
Dakai Hu
Dakai Hu el 17 de Mayo de 2021
Movida: Sabin el 24 de Dic. de 2022
Torque constant and permanent magnet flux linkage are always evaluated by peak values, whether its phase-to-neutral current or or phase-to-neutral voltage. So to answer your question it should be (N.m / A_peak).
Giovanni Pizzolante
Giovanni Pizzolante el 18 de Mayo de 2021
Movida: Sabin el 24 de Dic. de 2022
@Dakai Hu thank you very much.

Iniciar sesión para comentar.

Más respuestas (0)

Categorías

Más información sobre Specialized Power Systems en Help Center y File Exchange.

Community Treasure Hunt