I don't understand why the state space output doesn't match the transfer function model in Simulink.
I am sure that the PI controller is able to make the value converge to the one i need (30) in this case, but in the state space representation the output value doesn't converge to 30 and i don't understand why.
The values for the simulink models are the following:
J_M=0.00009;
B_M=0.01;
Lambda_PM=0.14294;
polepairs=3;
L=2.2e-4;
R=4.46;
a=-B_M/J_M;
c=1;
b=1.5*polepairs*Lambda_PM;
d=0;
The simulink file is attached, together with the results i get from it.
Thank you in advance :)

3 comentarios
Mathieu NOE
el 17 de Mayo de 2021
hi
could not run the simulink file because I have R2020b
but I noticed the two systems do have significant difference in DC gain - why not make things simpler and have same gain ? then you could use also same PID

% ss step response
figure(1),step(a,b,c,d)
% tf step response
num = b;
den = [J_M B_M];
figure(2),step(num,den)
Claudio Di Pietro
el 17 de Mayo de 2021
Mathieu NOE
el 18 de Mayo de 2021
My pleasure
Ciao