hi all
i just wanna ask,how we do the increasing value by changing manual switch in simulink??
for example: i have manual switch, with 2 constant block connect to it, first signal= 1 , second=0. i have calculation that everytime we change value in manual switch the system will add 10 to the current signal.
how we do it with embedded matlab function??
  1 comentario
Walter Roberson
Walter Roberson el 15 de Jul. de 2011
Duplicate is http://www.mathworks.com/matlabcentral/answers/11705-value-that-increase-along-with-changing-value-in-manual-switch-block-simulink

Iniciar sesión para comentar.

Respuesta aceptada

Fangjun Jiang
Fangjun Jiang el 15 de Jul. de 2011
Do you have to use EML? If not, it could be done easily in Simulink using a trigger subsystem. Type "sldemo_counters" to open the demo model, connect your manual switch block output to the triggered subsystem. Inside the system, change the trigger from "risgin" to "either", change the constant from 1 to 10 then you got it.

Más respuestas (4)

Walter Roberson
Walter Roberson el 15 de Jul. de 2011
Please do not open duplicate questions; it just ends up duplicating efforts.
You can edit your previous question if needed.

Kaustubha Govind
Kaustubha Govind el 15 de Jul. de 2011
FWIW, here's an EML implementation:
function y = mycounter(u)
%#eml
persistent count;
persistent prevInput;
firstInput = false;
if isempty(count)
count = 0;
end
if isempty(prevInput)
prevInput = 0;
firstInput = true;
end
if ~firstInput
if (prevInput ~= u)
count=count+1;
end
end
prevInput = u;
y = count;
end

Fangjun Jiang
Fangjun Jiang el 15 de Jul. de 2011
Okay, feed the switch output signal to the triggered subsystem, still choose "either". Also, feed the switch output signal to an Inport of the the triggered subsystem, multiple it by 10, then feed it to an Integrator block. Did not verify. Should work. Try it yourself.
  3 comentarios

Iniciar sesión para comentar.


Luhur
Luhur el 15 de Jul. de 2011
what if i have 3 signal fang??? -1,0,1 ,, if -1 then the current value was be diminished, 0 the value stay still and 1 the value increase.
  4 comentarios
Fangjun Jiang
Fangjun Jiang el 15 de Jul. de 2011
If 1 then current value is increased by 10. Increased only once, or every time step as long as the switch output is 1?
Luhur
Luhur el 15 de Jul. de 2011
no only once, the case was the same with the manual switch, but in this case there was 0 and -1 for minus it.
so when curent value is 10, then the signal give 1, then 10 + 10 = 20,, and then the signal gives 0, then 20 + 0 = 20,, and if the signal gives -1, then 20 - 10 = 10,,
so now, the current value is 10.
how is it fang???