Is it always customary to convert 4-Port S-Parameters to 2-Port S-Parameters and then plot Smith's chart ? Why ?
0 comentarios
Respuesta aceptada
Giorgia Zucchelli
el 15 de Sept. de 2014
Dear Jay,
Converting S-parameters can be done, but it is not compulsory. I can imagine that you might want to do it when you are interested only in a pair of ports (e.g. selecting a certain channel in multi-port measurements, and terminate all the other ports with a certain impedance), or if you want to translate single ended measurements to differential data. Plotting on a smith chart is then done to visualize the input or the output port behaviour.
With best regards,
Giorgia
Más respuestas (1)
Giorgia Zucchelli
el 16 de Sept. de 2014
Hi,
The RF Toolbox documetation references this article "Mixed-Mode S-Parameter Characterization of Differential Structures" by Fan, W., A. C. W. Lu, L. L. Wai, and B. K. Lok, published on Electronic Packaging Technology Conference, pp. 533–537, 2003.
I think that this is a good starting point to discuss the differences and the derivation between the two.
With best regards,
Giorgia